DC Injection Unit (DCIU)

GATR's DC Injection Unit is contained in a rugged, watertight enclosure (suitable for outdoor use). The unit provides a 10MHz Reference and power to both LNB and BUC on coaxial line in, can supply up to 120W (24V at 5A) to power BUC, and includes a monitor port for RX path.
Frequency Range: 950 MHz to 2000 MHz
RF Connections: N-type (50Ω)
Power:
| Input Power: | 24V |
| BUC Power: | 24V at 5A maximum (power is passed through from 24V input) |
| LNB Power: | 18V at 0.6A maximum |
10 MHz Output
Output Level: +3dBm +/-1 dB on both LNB and BUC lines
Frequency Stability: +/-50 ppb over operating temperature range
Phase Noise:
| Offset (Hz) | Level (dBc) |
| 1 | -90 |
| 10 | -120 |
| 100 | -140 |
| 1,000 | -145 |
| 10,000 | -150 |
| 100,000 | -152 |
Environment
Operating Temperature Range: -32°C to 55°C
Rain: Tested to MIL-STD-810G Method 506.5, Procedure I
Shock: Tested to MIL-STD-810G, Method 516.6, Procedure IV
Humidity: Tested to MIL-STD-810G, Method 507.5, Procedure II